CCRJQ - 00800 SILICONE LUBE, LUBRICANTS RUST (SUPP DATA)

  • MSDS: CCRJQ
  • Manufacturer: SHERWIN WILLIAMS CO
  • Product Name: 00800 SILICONE LUBE, LUBRICANTS RUST (SUPP DATA)
  • National Stock Number: 9150-00N074215
Product Identification

Product ID:00800 SILICONE LUBE, LUBRICANTS RUST (SUPP DATA)
MSDS Date:02/01/1992
FSC:9150
NIIN:00N074215
MSDS Number: CCRJQ

Responsible Party
SHERWIN WILLIAMS CO
6830 COCHRAN RD
SOLON, OH 44139
US

Emergency Phone: 216-292-7400

Info Phone: 800-777-2966

Cage: 54626

Contractor
SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
BEDFORD HEIGHTS, OH 44146 US

Telephone: 216-292-7400 OR 216-595-8634

Cage: 09800

Ingredients

760.

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 16%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT


16% BY WT EXCLUDING FEDERALLY

RTECS: 9999999VO


PROCS. CONTENTS UNDER PRESS. DO NOT PUNCTURE,

RTECS: 9999999ZZ


RADIATORS, STOVES, HOT WATER & OTHER HEAT SOURCES

RTECS: 9999999ZZ


OUT OF REACH OF CHILDREN. USE ONLY W/ADEQ VENT. AVOID

RTECS: 9999999ZZ


THIS COATING MAY CONTAIN MATLS CLASSIFIED AS NUISANCE

RTECS: 9999999ZZ


DURING SANDING/ABRADING OF DRIED FILM. IF NO SPECIFIC

RTECS: 9999999ZZ


NUISANCE DUSTS ARE ACGIH TLV 10 MG/M3 (TDUST), OSHA

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL &/OR SKIN/EYE
CONT, DEPENDING ON CNDTNS OF USE. TO MIN EXPOS, FOLLOW RECS FOR
PROPER USE, VENT & PERSONAL PROT EQUIP. ACUTE:IRRIT OF EYES, SKIN &
RESP SYS. MAY CAUSE NERV SYS DEP RESS. EXTREME OVEREXP MAY RSLT IN
UNCON& POSS DEATH. HDCH, DIZZ, NAUS & LOSS OF COORD ARE INDICATIONS
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:OF EXCESSIVE EXPOS TO VAPS/SPRAY
MISTS. REDNESS & ITCH/BURNING SENSATION MAY INDICATE EYE/EXCESSIVE
SKIN EXPOS. CHRONIC:PRLNG OVEREXP TO SOLV INGS MAY CAUSE ADVERSE
EFTS TO LIVER, URINARY, BL OOD-FORMING, CVS & REPRO SYS. RPTS
HAVEASSOC RPTD & PRLNG OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS
DMG. (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE. EYES:FLUSH W/LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.
INGEST:NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO
NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. SEEK MEDICAL
ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:<0F,<-18C
Lower Limits:0.7%
Upper Limits:12.8%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZ ARE PREF.
WATER MAY BE USED TO COOL CLSD CNTNRS TO (SUPDAT)
Unusual Fire/Explosion Hazard:EXTREMELY FLAMMABLE. CLOSED CONTAINERS
MAY EXPLODE (DUE TO BUILD-UP OF PRESSURE) WHEN EXPOSED TO EXTREME
HEAT.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DOL STOR CATEGORY-1A. CONTENTS ARE
EXTREMELY FLAMM. KEEP AWAY FROM HEAT, SPKS & OPEN FLAME. VAPS WILL
ACCUM READILY & MAY IGNITE EXPLOSIVELY.
Other Precautions:DURING USE & UNTIL ALL VAPS ARE GONE:KEEP AREA
VENTED; DO NOT SMOKE; EXTING ALL FLAMES, PILOT LIGHTS & HEATERS;
TURN OFF STOVES, ELEC TOOLS & APPLIANCES & ANY OTHER SOURCES OF
IGNIT. CONSULT NFPA CODE . USE APPRVD BONDING & GROUNDING (ING 3)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED NIOSH
APPROVED ORGANIC VAPOR/PARTICULATE RESPIRATOR FOR PROTECTIONS
AGAINST INGREDIENTS.
Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPT IF EXPOS
TO INGS IS MAINTAINED BELOW APPLIC EXPOS LIMS. REFER (SUPDAT)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:PREVENTATIVES & MAINTENANCE PRODUCTS - 3. FIRE
FIGHT PROC:PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOS TO
EXTREME HEAT. EFTS OF OVEREXP:INTENTIONAL MISUSE BY DELIB CO NC &
INHAL CONTENTS CAN BE HARMFUL/FATAL. VENT:TO OSHA STDS 1910.94,
1910.107, 1910.108.

Chemical Properties

Boiling Pt:B.P. Text:<395F,<202C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:>75

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
MONOXIDE, OXIDES OF METALS IN INGREDIENTS.

Disposal

Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
THE RCRA (40 CFR 261). WASTE MUST BE TESTED FOR IGNITABILITY TO
DETERMINE APPLIC EPA HAZ WASTE NUMBERS. DO NOT INCIN. DEPRESSURIZE
CNTNR. DISP OF I/A/W FED, STATE & LOC REGS REGARDING POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.